Our engineers are trained and certified installers and testers of Fall Arrest Eye Bolts to Class A1 Anchor Devices BS EN795 as outlined in BS 7883:2005
- We install these fixings in concrete, brick or stone including trial installation and tension testing and the issue of a test certificate
- Our installation and testing covers both the external and internal use of these devices
- We carry out periodic testing and examination of existing fixings including tension tests with all readings recorded in a detailed report
- The report states which fixings may remain in use and those which should be removed including the reasons why and recommended remedial action
- Method statements will be submitted for both the installation of new fixings and the tension testing of existing fixings